Power Installation
9
The following colors are used for pre-terminated wires:
120 VAC
(two wires plus ground)
120/240 VAC
(three wires plus ground)
Line 1 - Black
Line 1 - Black
Neutral – White
Line 2 - Red
Grounding – Green-Yellow
Neutral – White
Grounding – Green-Yellow
3.6 Power Routing in the Display
Check exact power routing on Drawing B-360218 found in Appendix A.
A general power routing is
shown in Figure 10.
1. Power terminates
internally to the
power termination
panel.
2. Power is routed
through filters to
the power supplies,
which provide
power to the
controller, MLC,
modules, and fans.
Power supplies are
preset to the proper
voltage: 12 VDC.
Figure 10: Power Flow Summary