Start-up Procedure

5.2 Start-up Sequence

Each time the display is turned on, an initialization sequence runs. Examples of the

information shown on the display are listed in the second column.

Attribute and Description

Example

Current Firmware Version Running on Display

M4-GalaxyProRev 4.X.X

Current Root File System Version Running on Display

Rfs X.X.X

Display Size

Row x Column

Display Color Type

Bit Depth of Display

RGB

32

Currently Configured Time Zone

America/North Dakota/Center

Current IP Address of Display (see note below)

Will vary

Name of Web Service and Port It Currently Runs On

Srvc: DisplayConfig

Port: 4500

Name of Web Service and Port It Currently Runs On

Srvc: DisplayStatus

Port: 4501

Name of Web Service and Port It Currently Runs On

Srvc: PlayerControl

Port: 4502

Name of Web Service and Port It Currently Runs On

Srvc: SecurityManagement

Port: 4503

Name of Web Service and Port It Currently Runs On

Srvc: FileTransfer

Port: 4504

Name of Connected Sensor and Its Offset (Address)

Sensor: TEMP

Offset: Addr: 1

Name of Connected Sensor and Its Offset (Address)

Sensor: LIGHT_LUX

Offset: Addr: 2

User-Defined Display Description

East Employee Entrance

Note: There are two Ethernet ports – Port 0 on the top and Port 1 on the bottom. Using Port 1

is preferred. During the start-up sequence, each port returns its status. When a port is not

used, the display will show “not found”. The port that is used returns the IP address.

The order of services and sensors could change. After this sequence is complete, the display

will blank. A single pixel will flash in the lower-right corner of the display to show that the

display has power, but no presentations are currently running.

5.3 Post Installation Checklist

Verify the following after starting the display:

Assure all ventilation fans are fully operational.

Inspect all intake and exhaust vents for obstruction.

Confirm proper communications from the control computer to the display(s).

Assure proper communications between display faces when applicable.