Comtech EF Data MBT-4000B User Manual
Page 62
Multi-Band Transceiver System
Revision 0
Remote Command
MN/MBT4000B.IOM
A-26
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes
between 48 and 57)
Response to
Command
(target to controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Serial Number
N/A
All
9 bytes, numeric
000000000 to
999999999
Query only.
Used to Query the units 9 digit serial number.
Slave returns its S/N, in the form xxxxxxxxx.
Example: RSN=000000165
N/A RSN?
RSN=xxxxxxxx
x
(see
description for
details of
arguments)
Retrieve
Utility Status
N/A MBT 24
bytes
alphanumeric
Query only.
Used to Query the utility status of the MBT-4000B base
unit..
Example:
<0001/RUS={cr}
>0001/RUS={cr}{lf}
ADR=0001{cr}
BDR=9600{cr}{lf}
N/A RUS?
RUS=x….x
(see
description for
details of
arguments)
Remote Baud
Rate
SBR=xxxx MBT
4
bytes,
Command or Query.
Set remote baud rate as follows:
9600 = 9600 baud
19K2 = 19200 baud
SBR= (message ok)
SBR? (received ok, but
invalid arguments
found)
SBR! (Command not
accepted by BUC and
BDC sub-units.)
SBR?
SBR=xxxx
(same format
as command
arguments)
Summary Fault
Status
N/A All N/A
Query only.
Used to Query the status of the Summary Fault Relay.
Where:
0=OK
1=FT
Example: SFS?
N/A SFS?
SFS=x
(see
description for
details of
arguments)
Remote Address
SPA=xxxx
MBT
4 byte,
numeric
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412
SPA= (message ok)
SPA? (received ok, but
invalid arguments
found)
SPA! (Command not
accepted by BUC and
BDC sub-units.)
SPA?
SPA=xxxx
(same format
as command
arguments)