Comtech EF Data MBT-4000B User Manual
Page 45
Multi-Band Transceiver System
Revision 0
Remote Command
MN/MBT4000B.IOM
9
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid
on
MBT,
BDC,
or
BUC
Arguments
for
Command
or Response
to Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that is, ASCII codes
between 48 and 57)
Response to
Command
(target to
controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Automatic
Fault
Recovery
State
AFR=x All
1 byte, value
of 0, 1
Command or Query.
Enable Automatic Fault Recovery on a BXC as follows:
0=Disabled
1=Enabled
Example: AFR=1
AFR=(message
ok)
AFR? (received ok,
but invalid
arguments found)
AFR*(message ok,
but not permitted in
current mode)
AFR? AFR=x
(same format
as command
arguments)
Attenuation ATT=xx.xx BDC
BUC
5 bytes,
numeric
Command or Query
Valid attenuation level, in dB, at 0.25dB step size as factory default.
Example: ATT=08.25
ATT=(message ok)
ATT? (received ok,
but invalid
arguments found)
ATT*(message ok,
but not permitted in
current mode)
ATT! (Command
not accepted by
MBT-4000B base
unit. It must be
addressed to BUC
or BDC sub-units)
Clear All
Stored
Alarms
CAA= All None Command
only.
Instructs the slave to clear all Stored Events.
This command takes no arguments.
CAA=(message
ok)
N/A N/A