beautypg.com

Comtech EF Data MBT-4000B User Manual

Page 45

background image

Multi-Band Transceiver System

Revision 0

Remote Command

MN/MBT4000B.IOM

9

Parameter

Type

Command

(Instruction

Code and

qualifier)

Valid

on

MBT,
BDC,

or

BUC

Arguments

for

Command

or Response

to Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that is, ASCII codes

between 48 and 57)

Response to

Command

(target to

controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Automatic

Fault

Recovery

State

AFR=x All

1 byte, value

of 0, 1

Command or Query.
Enable Automatic Fault Recovery on a BXC as follows:
0=Disabled
1=Enabled

Example: AFR=1

AFR=(message
ok)
AFR? (received ok,
but invalid
arguments found)
AFR*(message ok,
but not permitted in
current mode)

AFR? AFR=x

(same format

as command

arguments)

Attenuation ATT=xx.xx BDC

BUC

5 bytes,
numeric

Command or Query
Valid attenuation level, in dB, at 0.25dB step size as factory default.

Example: ATT=08.25

ATT=(message ok)
ATT? (received ok,
but invalid
arguments found)
ATT*(message ok,
but not permitted in
current mode)
ATT! (Command
not accepted by
MBT-4000B base
unit. It must be
addressed to BUC
or BDC sub-units)

Clear All

Stored

Alarms

CAA= All None Command

only.

Instructs the slave to clear all Stored Events.
This command takes no arguments.

CAA=(message
ok)

N/A N/A