COMM I/O
N/A MBT
n=Slot
1=AUX
COMM 1
Query only.
Used to Query the Concise AUX COMM I/O of the MBT-
4000B base unit, where n=1
Where:
n=1(AUX COMM 1)
Example:
<0001/CAI?n{cr}
>0001?CAI=nabcd{cr}{lf}
Where:
n=1 (AUX COMM)
a=12V (0=Off, 1=On)
b=IOA (O=logic low [voltage input < 0.5],
1=logic high [voltage input > 2.7 vdc)
c=IOB (O=logic low [voltage input < 0.5],
1=logic high [voltage input >2.7 vdc]
d=Reserved (Always zero)
CAI=(message ok)
CAI? (received ok, but invalid
arguments found)
CAI*(message ok, but not
permitted in current mode)
CAI?n CAI=nabcd
(see
description for
details of
arguments)