beautypg.com

Comtech EF Data MBT-4000B User Manual

Page 46

background image

Multi-Band Transceiver System

Revision 0

Remote Command

MN/MBT4000B.IOM

A-10

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Valid on

MBT,

BDC, or

BUC

Arguments

for

Command

or

Response

to Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that

is, ASCII codes

between 48 and 57)

Response to Command

(Target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(Target to

controller)

Concise

AUX

COMM I/O

N/A MBT

n=Slot
1=AUX
COMM 1

Query only.
Used to Query the Concise AUX COMM I/O of the MBT-
4000B base unit, where n=1
Where:
n=1(AUX COMM 1)


Example:
<0001/CAI?n{cr}
>0001?CAI=nabcd{cr}{lf}


Where:
n=1 (AUX COMM)
a=12V (0=Off, 1=On)
b=IOA (O=logic low [voltage input < 0.5],
1=logic high [voltage input > 2.7 vdc)
c=IOB (O=logic low [voltage input < 0.5],
1=logic high [voltage input >2.7 vdc]
d=Reserved (Always zero)

CAI=(message ok)
CAI? (received ok, but invalid
arguments found)
CAI*(message ok, but not
permitted in current mode)

CAI?n CAI=nabcd

(see

description for

details of

arguments)