Comtech EF Data MBT-4000B User Manual

Page 58

background image

Multi-Band Transceiver System

Revision 0

Remote Command

MN/MBT4000B.IOM

A-22

Parameter

Type

Command

(Instruction

Code and

qualifier)

Valid on

MBT,

BDC, or

BUC

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that is,

ASCII codes

between 48 and 57)

Response to

Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Retrieve

Alarm Status

N/A

All

92 bytes MBT-

4000B

64 bytes

(BUC),

74 bytes

(BDC),

alphanumeric

Query only.
Used to Query the Alarm status of the unit

Example for MBT-4000B base:

<0001/RAS?{cr}
>0001/RAS={cr}
15VT1=OK{cr}
7V5T1=OK{cr}
5VLT1=OK{cr}
28VT1=OK{cr}
REFLD=OK{cr}
IICST=OK{cr}
LNAC1=OK{cr} (Note 2)
LNAC2=OK{cr} (Note 2)
LNAW1=OK{cr} (Note 3)
LNAW2=OK{cr} (Note 3)
LNAI1=OK{cr} (Note 4)
LNAI2=OK{cr}{lf} (Note 5)

Example for BDC or BUC:

<0001A1/RAS?{cr}
>0001A1/RAS={cr}
15VLT=OK{cr}
7V5LT=OK{cr}
5VOLT=OK{cr}
REFLD=XX {cr} (reserved for future use)
SYNLD=OK{cr}
HSTMP=OK{cr}
LNACR=OK{cr}{lf}


Notes:

1. LNACR will only appear for BDC.
2. FT reported if MAX current exceeded.
3. FT reported if LCW window current exceeded.
4. FT reported if EAM = 11 & Pin F of J9 High.
5. FT reported if EAM = 21 & Pin F of J8 High, not

applicable to MBT-4000B.

N/A RAS?


RAS=x….x

(see
description for
details of
arguments)