Comtech EF Data MBT-4000B User Manual
Page 58
Multi-Band Transceiver System
Revision 0
Remote Command
MN/MBT4000B.IOM
A-22
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that is,
ASCII codes
between 48 and 57)
Response to
Command
(target to controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Retrieve
Alarm Status
N/A
All
92 bytes MBT-
4000B
64 bytes
(BUC),
74 bytes
(BDC),
alphanumeric
Query only.
Used to Query the Alarm status of the unit
Example for MBT-4000B base:
<0001/RAS?{cr}
>0001/RAS={cr}
15VT1=OK{cr}
7V5T1=OK{cr}
5VLT1=OK{cr}
28VT1=OK{cr}
REFLD=OK{cr}
IICST=OK{cr}
LNAC1=OK{cr} (Note 2)
LNAC2=OK{cr} (Note 2)
LNAW1=OK{cr} (Note 3)
LNAW2=OK{cr} (Note 3)
LNAI1=OK{cr} (Note 4)
LNAI2=OK{cr}{lf} (Note 5)
Example for BDC or BUC:
<0001A1/RAS?{cr}
>0001A1/RAS={cr}
15VLT=OK{cr}
7V5LT=OK{cr}
5VOLT=OK{cr}
REFLD=XX {cr} (reserved for future use)
SYNLD=OK{cr}
HSTMP=OK{cr}
LNACR=OK{cr}{lf}
Notes:
1. LNACR will only appear for BDC.
2. FT reported if MAX current exceeded.
3. FT reported if LCW window current exceeded.
4. FT reported if EAM = 11 & Pin F of J9 High.
5. FT reported if EAM = 21 & Pin F of J8 High, not
applicable to MBT-4000B.
N/A RAS?
RAS=x….x
(see
description for
details of
arguments)