Comtech EF Data MBT-4000B User Manual
Page 51
Multi-Band Transceiver System
Revision 0
Remote Command
MN/MBT4000B.IOM
A-15
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that is,
ASCII codes
between 48 and 57)
Response to
Command
(target to
controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Concise
Utility Status
N/A MBT
21
bytes
alphanumeric
Query only.
Used to query the utility status of the MBT-4000 Base Unit,
response is comma delimited.
Where:
aaaa=Physical Address
bbbb=Remote Baud Rate
Example:
<0001/CUS?
>0001/CUS=aaaa,bbbb{cr}{lf}
N/A CUS?
CUS=x…x
(see
description for
details of
arguments)
Set RTC
(Real-Time-
Clock) Date
DAT=mmddyy All
6
bytes,
numeric
Command or Query.
A command in the form mmddyy
where;
dd = day of the month, between 01 and 31
mm = month of the year, between 01 and 12
yy = year, between 00 and 96 (2000 to 2096)
Example: DAT=042503 would be April 24, 2003.
DAT= (message
ok)
DAT? (received
ok, but invalid
arguments found)
DAT* (message
ok, but not
permitted in
current mode)
DAT?
DAT=mmddyy
(same format
as command
arguments)
Enable Aux
Com
Fault Input
Monitoring
EAM=nm MBT
n=1
AUX
COMM1
m=0
(disabled), 1
(monitoring
enabled)
Command or Query.
EAM controls monitoring of external fault logic inputs to Aux Comm
connectors (J9 pin F). If enabled and external fault input is at Logic
1 ( > 2.6 vdc) a fault will be reported. This fault is reported has the
LNA I1 or LNA I2 status in the RAS? Query.
Note: The inputs may be driven by a contact closure relay. They
have an internal pull-up resistor (4.7k) to +5 vdc.
Example: EAM=11
EAM=(message
ok)
EAM?(received
ok, but invalid
arguments found)
EAM?n EAM=nm
(same format
as command
arguments)