Multi-Band Transceiver System

Revision 0

Remote Command

MN/MBT4000B.IOM

A-15

Parameter

Type

Command

(Instruction

Code and

qualifier)

Valid on

MBT,

BDC, or

BUC

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that is,

ASCII codes

between 48 and 57)

Response to

Command

(target to

controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Concise

Utility Status

N/A MBT

21

bytes

alphanumeric

Query only.
Used to query the utility status of the MBT-4000 Base Unit,
response is comma delimited.

Where:
aaaa=Physical Address
bbbb=Remote Baud Rate

Example:
<0001/CUS?
>0001/CUS=aaaa,bbbb{cr}{lf}


N/A CUS?

CUS=x…x

(see

description for

details of

arguments)

Set RTC

(Real-Time-
Clock) Date

DAT=mmddyy All

6

bytes,

numeric

Command or Query.
A command in the form mmddyy
where;
dd = day of the month, between 01 and 31
mm = month of the year, between 01 and 12
yy = year, between 00 and 96 (2000 to 2096)

Example: DAT=042503 would be April 24, 2003.

DAT= (message
ok)
DAT? (received
ok, but invalid
arguments found)
DAT* (message
ok, but not
permitted in
current mode)

DAT?

DAT=mmddyy

(same format
as command
arguments)

Enable Aux

Com

Fault Input
Monitoring

EAM=nm MBT

n=1

AUX

COMM1

m=0
(disabled), 1
(monitoring
enabled)

Command or Query.
EAM controls monitoring of external fault logic inputs to Aux Comm
connectors (J9 pin F). If enabled and external fault input is at Logic
1 ( > 2.6 vdc) a fault will be reported. This fault is reported has the
LNA I1 or LNA I2 status in the RAS? Query.

Note: The inputs may be driven by a contact closure relay. They
have an internal pull-up resistor (4.7k) to +5 vdc.

Example: EAM=11

EAM=(message
ok)
EAM?(received
ok, but invalid
arguments found)

EAM?n EAM=nm

(same format

as command

arguments)