Multi-Band Transceiver System

Revision 0

Remote Command

MN/MBT4000B.IOM

A-17

Parameter

Type

Command

(Instruction

Code and

qualifier)

Valid on

MBT,

BDC, or

BUC

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that

is, ASCII codes

between 48 and 57)

Response to

Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

LNA/LNB Current

Window

LCW=sxx MBT

BDC

s=1 byte,

value of 1, 2

1=LNA A
2=LNA B

xx=2 bytes,

numeric

Command or Query.
This command allows the user to set the alarm window in

±

% of the calibrated LNA/LNB bias Current. Valid inputs are
20 to 50 in increments of 1%. In addition, setting the value
to 99 disables the alarm function.

Default is disabled.

Example: LCW=230, set alarm window for the LNB bias tee
to

± 30%.

LCW= (message ok)
LCW? (received ok, but
invalid arguments
found)
LCW* (message ok, but
not permitted in current
mode)
LCW! (command not
accepted by BUC or
BDC sub-units)

LCW?s LCW=sxx


(same format
as command
arguments)

LNA/LNB Fault

Logic

LFL=sx MBT

BDC

s=1 byte,

value of 1, 2

1=LNA A

2=LNB bias tee

x=1 byte,

Value of 0, 1

0 = Disable

1 = Enable

Command or Query.
Allows LNA/LNB Fault Logic to contribute to the summary
fault relay as follows:

Source Enable
1=LNA A (Aux Comm 1)

0 = Disabled

2=LNB bias tee

1 = Enabled


Example: LFL=21 would generate a fault if the measured
current for the bias tee varied from the calibrated operating
point stored by the CLC=2 command more the % allowed
by the LCW=2xx command

LFL= (message ok)
LFL? (received ok, but
invalid arguments
found)
LCS* (message ok, but
not permitted in current
mode)
LFL! (command not
accepted by BUC or
BDC sub-units)

LFL?s

s=1 byte,

Value of 1, 2

LFL=sx

(same format
as command
arguments)