Comtech EF Data MBT-4000B User Manual
Page 50
Multi-Band Transceiver System
Revision 0
Remote Command
MN/MBT4000B.IOM
A-14
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that is,
ASCII codes between
48 and 57)
Response to
Command
(target to
controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Concise
Maintenance
Status
N/A All 40
bytes
alphanumeric
Query only.
Used to query the maintenance status of the unit in concise format.
Response is comma delimited as follows:
Example:
<0001/CMS?{cr}
>0001/CMS=aaa.a,bbb.b,ccc.c,ddd.d,eee.e,fff.f,
ggg.g,h,I,j,k{cr} {lf}
All:
aaa.a=+15V power supply
bbb.b=+7.5V power supply
ccc.=+5V power supply
MBT-4000B Base Unit:
ddd.d=+28V power supply
eee.e=Ref oscillator tuning voltage
fff.f=LNA current in mA for LNA A (AUX COMM1)
ggg.g= LNB current in mA for the bias tee
h=local RF switch position (A, B, or N)
i=Local IF switch position (A, B, or N)
j=Remote RF switch position (A or B)
k=Remote IF switch position (A or B)
Note:
1.
It is not possible to detect the absence of a remote switch.
2.
N= Not present.
BDC:
ddd.d=XXX.X (reserved for future use)
eee.e=Synthesizer tuning voltage
fff.f=LNA current in mA.
ggg.g= Unit temperature in
°C.
h – k= Not present
BUC:
ddd.d=XXX.X (reserved for future use)
eee.e=Synthesizer tuning voltage
fff.f=RF output power in dBm (reserved)
ggg.g=Unit temperature in
°C
h – k= Not present
N/A CMS?
CMS=…
(see description
for details of
arguments)