beautypg.com

Comtech EF Data MBT-4000B User Manual

Page 59

background image

Multi-Band Transceiver System

Revision 0

Remote Command

MN/MBT4000B.IOM

A-23

Parameter

Type

Command

(Instruction

Code and

qualifier)

Valid on

MBT,

BDC, or

BUC

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that is,

ASCII codes

between 48 and 57)

Response to

Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Retrieve

Configuration

Status

N/A

All

65 bytes (MBT-

4000B)

98 bytes

(BDC),

76 bytes (BUC)

alphanumeric

Query only.
Used to Query the configuration status of the unit

Example for MBT-4000B base:

<0001/RCS?{cr}
>0001/RCS={cr}
BF1=X {cr}
BF2=X {cr}
BT1=DN{cr}
BT2=UP{cr}
RED=0{cr}
RAM=00{cr}
MBT=N, A, or B
EXT=0{cr}{lf}

Example for BDC or BUC:

<0001A1/RCS?{cr}
>0001A1/RCS={cr}
FLO=06300{cr}
ATT=01.00{cr}
MUT=1{cr}
SLP=0.3{cr}
LCS=0{cr}
LCW=99{cr}
LFL=1{cr}
REF=XXXX{cr} (reserved for future use)
XRE=X{cr} (reserved for future use)
AFR=0{cr}{lf}


Note: for BUC, LCS, LCW, & LFL will not be shown.

N/A RCS?


RCS=x….x

(see
description for
details of
arguments)