beautypg.com

Comtech EF Data SMS-758 User Manual

Page 69

background image

SMS-758 Modem Protection Switch

Theory of Operation

MN/SMS758 Rev. 3

4–9

Table 4-5. Relay-Remote Command Functions

Function

Description

AUTO

Executed only from REMOTE mode. This function places the switch in
the automatic mode of operation.

REMOTE

Executed from any operating mode other than REMOTE; must be
executed before any other relay-remote function. This function places
the switch in the remote mode of operation.

BACKUP MOD 1

Executed only from REMOTE mode. This function is used to place
backup modulator 1 online when it precedes a target word, or offline
when it precedes EXECUTE.

BACKUP MOD 2

Executed only from REMOTE mode. This function is used to place
backup modulator 2 online when it precedes a target word, or offline
when it precedes EXECUTE.

BACKUP DEMOD 1

Executed only from REMOTE mode. This function is used to place
backup demodulator 1 online when it precedes a target word, or
offline when it precedes EXECUTE.

BACKUP DEMOD 2

Executed only from REMOTE mode. This function is used to place
backup demodulator 2 online when it precedes a target word, or
offline when it precedes EXECUTE.

Table 4-6. Relay-Remote Command Examples

Input Lines

Command Words

Rem3

Rem2

Rem1

Rem0

Comments

START

C

C

C

C

Places the M:N in the remote

REMOTE

N

N

N

C

mode.

EXECUTE

C

C

N

N

START

C

C

C

C

Places B/U modulator 1 online for

B/U MOD 1

C

C

N

C

prime 2.

TARGET PRIME 2

N

N

C

N

EXECUTE

C

C

N

N

START

C

C

C

C

Places B/U modulator 2 online for

B/U MOD 2

C

C

C

N

prime 6.

TARGET PRIME 6

N

C

C

N

EXECUTE

C

C

N

N

START

C

C

C

C

Places B/U demodulator 1 online

B/U DEMOD 1

C

N

N

C

for prime 5.

TARGET PRIME 5

N

C

N

C

EXECUTE

C

C

N

N

START

C

C

C

C

Place B/U demod 2 offline.

B/U DEMOD 2

C

N

C

N

(No target word.)

EXECUTE

C

C

N

N

START

C

C

C

C

Places the M:N in the auto mode.

AUTO

N

N

C

N

EXECUTE

C

C

N

N

C = Change of state. N = No change of state.
Mod = Modulator. Demod = Demodulator.