beautypg.com

2 external rs485 and rs232 interface (j1 and j2), 3 modem control rs485 – Comtech EF Data SMS-758 User Manual

Page 34

background image

Installation

SMS-758 Modem Protection Switch

2–6

MN/SMS758 Rev. 3

2.4.2 External RS485 and RS232 Interface (J1 and J2)

The external interface connectors provide serial remote interface to the switch. An
external controller can connect through J1 (RS-485) or J2 (RS-232C).

Use M&C module switch pack SP1 switch 5 (SP1-5) to configure each switch for
external remote interface type, either RS-485 or RS-232C. The ON position (nearer the
PCB) selects RS-232C interface, and OFF selects RS-485.

The external interface connectors are 9-pin female D connectors with screw locks for
mechanical security. The remote connector is a DCE interface.

RS-485

RS-232C

Pin Number

Name

Pin Number

Name

1

GND

1

2

2

RD (RX)

3

3

TD (TX)

4

+RX/TX

4

5

RX/TX

5

GND

6

6

7

7

8

+RX/TX

8

9

-RX/TX

9

2.4.3 Modem Control RS485

The prime and backup modems connect to the switch through J3, the modem control
interface connector. This connector provides the bus-type control interface required for
system operation.

Refer to Sections 4.2.2, 4.2.3, and the remote specifications (Appendixes A and B) for a
complete explanation of the remote interface functions.

Refer to the RS-485 pinout listed in Section 2.4.2