A.3.5.6.2 verify prime modem configuration, A.3.5.6.3 verify backup modem configuration, A.3.5.7.2 demodulator operational faults status – Comtech EF Data SMS-758 User Manual
Page 136

Remote Control Operation
SMS-758 Modem Protection Switch
A–14
MN/SMS758 Rev. 3
A.3.5.6.2 Verify Prime Modem Configuration
Command:
Response: >add/VMC_x”cr” Where: x = 1 to 8 (prime modem number). A.3.5.6.3 Verify Backup Modem Configuration Command: Response: >add/VMC_Bx”cr” Where: x = 1 or 2 (backup modem number). A.3.5.7 Operational Status Commands (Faults) A.3.5.7.1 Modulator Operational Faults Status Command: Response: >add/MOF_”cr” BU_OP_FLT_xxxxxxxx”cr””lf”] Backup operation faults (see Note) Where: x = 1 to 8 (prime mod number). Note: Fault status data is only returned if fault conditions exist. A.3.5.7.2 Demodulator Operational Faults Status Command: Response: >add/DOF_”cr” BU_OP_FLT_xxxxxxxx”cr” Backup operation faults (see Note) DL_FLT_yyy”cr””lf”] All Demods on downlink “y” faulted (see Note) Where: x = 1 to 8 (prime demod number). Note: Fault status data is only returned if fault conditions exist.
MOD_x_yyy”cr”
DMD_x_yyy”cr””lf”]
yyy = OK or FLT.
MOD_Bx_yyy”cr”
DMD_Bx_yyy”cr””lf”]
yyy = OK or FLT.
y = 1, 2, 3, or 4 (faulted downlink number).