B.3.3.4 Backup Modem Interface Type
Command:
Response: >add/INT_Bx_y”cr””lf”] Status Only: Response: >add/INT_Bx_y”cr””lf”] Where: x = 1 or 2 (backup modem number). y = 1 (for 15 D), 2 (for V.35), 3 (for RS-422), 4 (for DCTN), 5 (for IDR), B.3.4 Status Commands/Responses B.3.4.1 Configuration Status B.3.4.1.1 Prime Modulator Configuration Status The Modulator Configuration Status command causes a block of data to be returned by Command: Response: >add/MCS_x”cr” MA_yyy”cr” mod active (YES/NO) MP_y”cr” mod priority (1, 2, or 3) MD_yyy.y”cr” mod online delay ADD_yyy”cr” modem address INT_y”cr””lf”] modem interface type Where: x = 1 to 8 (prime modulator number). B.3.4.1.2 Backup Modulator Configuration Status The Modulator Configuration Status command causes a block of data to be returned by Command: Response: >add/MCS_Bx”cr” MA_yyy”cr” mod active (YES/NO) ADD_yyy”cr” modem address INT_y”cr””lf”] modem interface type
6 (for OTHER), 7 (for IBS), 8 (for D&I), or 9 (for IDR 2:N).
the SMS-758. The block of data reflects the stored configuration of the modulator
selected.
the SMS-758. The block of data reflects the stored configuration of the modulator
selected.