A.3.4.2 modulator status, A.3.4.3 demodulator status, A.3.4.4 prime modem fault status – Comtech EF Data SMS-758 User Manual
Page 131
SMS-758 Modem Protection Switch
Remote Control Operation
MN/SMS758 Rev. 3
A–9
A.3.4.2 Modulator Status
The modulator status is returned as a block of data which provides basic status
information of all “active” modulators. B1 and B2 are the backup modulators.
Command:
Response: >add/MS_”cr” Where: yyy = OK or FLT. A.3.4.3 Demodulator Status The demodulator status is returned as a block of data which provides basic status Command: Response: >add/DS_”cr” Where: yyy = OK or FLT. A.3.4.4 Prime Modem Fault Status Command: Response: >add/MFS_x”cr” MOD_xxx”cr” Mod Status (OK/FLT) DMD_xxx”cr””lf”] D emod Status (OK/FLT) Where: x = 1 to 8 (prime modem number).
MOD_1_yyy”cr”
MOD_2_yyy”cr”
MOD_3_yyy”cr”
MOD_4_yyy”cr”
MOD_5_yyy”cr”
MOD_6_yyy”cr”
MOD_7_yyy”cr”
MOD_8_yyy”cr”
MOD_B1_yyy”cr”
MOD_B2_yyy”cr””lf”]
information of all “active” demodulators. B1 and B2 are the backup demodulators.
DMD_1_yyy”cr”
DMD_2_yyy”cr”
DMD_3_yyy”cr”
DMD_4_yyy”cr”
DMD_5_yyy”cr”
DMD_6_yyy”cr”
DMD_7_yyy”cr”
DMD_8_yyy”cr”
DMD_B1_yyy”cr”
DMD_B2_yyy”cr””lf”]