SMS-758 Modem Protection Switch

Remote Control Operation

MN/SMS758 Rev. 3

A–7

A.3.3.5 Modem Priority

Command:

Response:

>add/MP_x_y”cr””lf”]

Status Only:

Response:

>add/MP_x_y”cr””lf”]

Where:

x = 1 to 8 (prime modem number).
y = 1, 2, or 3 (1 is high priority, 2 is medium priority, and 3 is low priority).

A.3.3.6 Modem Online Delay

Command:

Response:

>add/MD_x_yyy.y”cr””lf]

Status Only:

Response:

>add/MD_x_yyy.y”cr””lf]

Where:

x = 1 to 8 (prime modem number).
yyy.y = .5 to 127 (time in increments of .5 seconds), AUTO, or NONE.

A.3.4 Status Commands/Responses

A.3.4.1 Configuration Status

A.3.4.1.1 Prime Modulator Configuration Status

The Prime Modulator Configuration Status command causes a block of data to be
returned by the SMS-758. The block of data reflects the stored configuration of the
modulator selected.

Command:

Response:

>add/MCS_x”cr”

MA_yyy”cr”

Mod Active (YES/NO)

MP_y”cr”

Modem Priority (1, 2, or 3)

MD_yyy.y”cr”

Modem Online Delay

ADD_yyy”cr”

Modem Address

INT_y”cr””lf”]

Modem Interface Type

Where: x = 1 to 8 (prime modulator number).