B.3.3 modem configuration commands/responses, B.3.3.2 backup modem address, B.3.3.3 prime modem interface type – Comtech EF Data SMS-758 User Manual
Page 151

SMS-758 Modem Protection Switch
Remote Control Operation
MN/SMS758 Rev. 3
B–7
B.3.3 Modem Configuration Commands/Responses
B.3.3.1 Prime Modem Address
Address “0” may be used to clear the address field of modem “x”.
Command:
Response: >add/ADD_x_yyy”cr””lf”] Status Only: Response: >add/ADD_x_yyy”cr””lf”] Where: x = 1 to 8 (prime modem number). B.3.3.2 Backup Modem Address Address “0” may be used to clear the address field of modem “x”. Command: Response: >add/ADD_Bx_yyy”cr””lf”] Status Only: Response: >add/ADD_Bx_yyy”cr””lf”] Where: x = 1 to 8 (backup modem number). B.3.3.3 Prime Modem Interface Type Command: Response: >add/INT_x_y”cr””lf”] Status Only: Response: >add/INT_x_y”cr””lf”] Where: x = 1 to 8 (prime modem number). y = 1 (for 15 D), 2 (for V.35), 3 (for RS-422), 4 (for DCTN), 7 (for IBS), 8 (for D&I),
yyy = 1 to 255 (prime modem address).
yyy = 1 to 255 (backup modem address).
5 (for IDR), 6 (for OTHER), or 9 (for IDR 2:N).