beautypg.com

B.3.2 demodulator configuration commands/responses, B.3.1.4 backup modulator active, B.3.2.2 prime demodulator priority – Comtech EF Data SMS-758 User Manual

Page 149

background image

SMS-758 Modem Protection Switch

Remote Control Operation

MN/SMS758 Rev. 3

B–5

B.3.1.4 Backup Modulator Active

Command:

Response:

>add/MA_Bx_yyy”cr””lf”]

Status Only:

Response:

>add/MA_Bx_yyy”cr””lf”]

Where:

x = 1 or 2 (backup modulator number).
yyy = YES or NO.

B.3.2 Demodulator Configuration Commands/Responses

B.3.2.1 Prime Demodulator Active

Command:

Response:

>add/DA_x_yyy”cr”

Status Only:

Response:

>add/DA_x_yyy”cr””lf”]

Where:

x = 1 to 8 (prime demodulator number).
yyy = YES or NO.

B.3.2.2 Prime Demodulator Priority

Command:

Response:

>add/DP_x_y”cr””lf”]

Status Only:

Response:

>add/DP_x_y”cr””lf”]

Where:

x = 1 to 8.
y = 1, 2, or 3 (1 is high priority, 2 is medium priority, and 3 is low priority).