B.3.5.8.5 bulk consolidated status faults – Comtech EF Data SMS-758 User Manual
Page 162
Remote Control Operation
SMS-758 Modem Protection Switch
B–18
MN/SMS758 Rev. 3
B.3.5.8.5 Bulk Consolidated Status Faults
This command causes all switch fault status to be returned. To reduce the length of the
response, fault status is embedded into the bit structure of the characters that are
returned. Faults are indicated by a binary 1 in the designated bit position.
Command:
Response: >add/BCSF_”a””b””c”...”x””y””z””aa””ab””ac””ad””ae””cr””lf”] Character “a”: Modulator fault status character 1. Bit 6 = 1 always. Character “b”: Modulator fault status character 2. Bit 6 = 1 always. Character “c”: Demodulator fault status character 1. Bit 6 = 1 always. Character “d”: Demodulator fault status character 2. Bit 6 = 1 always. Character “e”: Modulator operational fault status character 1. Bit 6 = 1 always.
Bit 5 = Prime modulator #1 fault.
Bit 4 = Prime modulator #2 fault.
Bit 3 = Prime modulator #3 fault.
Bit 2 = Prime modulator #4 fault.
Bit 1 = Prime modulator #5 fault.
Bit 0 = Prime modulator #6 fault.
Bit 5 = Prime modulator #7 fault.
Bit 4 = Prime modulator #8 fault.
Bit 3 = Backup modulator #1 fault.
Bit 2 = Backup modulator #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Bit 5 = Prime demodulator #1 fault.
Bit 4 = Prime demodulator #2 fault.
Bit 3 = Prime demodulator #3 fault.
Bit 2 = Prime demodulator #4 fault.
Bit 1 = Prime demodulator #5 fault.
Bit 0 = Prime demodulator #6 fault.
Bit 5 = Prime demodulator #7 fault.
Bit 4 = Prime demodulator #8 fault.
Bit 3 = Backup demodulator #1 fault.
Bit 2 = Backup demodulator #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Bit 5 = Prime modulator #1 backup operational fault.
Bit 4 = Prime modulator #2 backup operational fault.
Bit 3 = Prime modulator #3 backup operational fault.
Bit 2 = Prime modulator #4 backup operational fault.
Bit 1 = Prime modulator #5 backup operational fault.
Bit 0 = Prime modulator #6 backup operational fault.