5 m&c board connector pinouts, 1 rs-232/485 remote control (j1), 2 remote relay control, j2 db15-female – Comtech EF Data KST-12000 User Manual
Page 90

KST-12000 Ku-Band Satellite Terminal
Revision 4
Theory of Operation
MN/KST12000.IOM
5.1.5 M&C Board Connector Pinouts
5.1.5.1 RS-232/485 Remote Control (J1)
The remote interface is provided on a 9-pin female D connector. Screw locks are
provided for mechanical security of the mating connector. The remote connector is a Data
Circuit Terminating Equipment (DCE) interface.
Pin #
RS-232
RS-485
Description
1 GND
GND Ground
2 TD/TX
Transmit
Data
3 RD/RX
Receive
Data
4
+RX/TX
Plus Transmit or Receive
5 GND
-RX/TX Negative
Transmit or Receive
6
DSR
Data Set Ready
7
RTS
Ready to Send
8
CTS
+RX/TX
Clear to Send (RS-485 — Plus Transmit or Receive)
9
-RX/TX
Negative Transmit or Receive Data
Notes:
1. Clear to Send (CTS) is tied to Ready to Send (RTS) in RS-232 mode.
2. Pinout for Data Terminal Equipment (DTE) interface is provided for RS-232.
5.1.5.2 Remote Relay Control, J2 DB15-Female
Pin #
Name
Description
1
EXT 10V
Output voltage, 10V at 1000 mA
9
LNA PWR
Output, 11V
2
DL FLT NO
Downlink FLT, Opens on FLT
10 DL
COM
DL
3
DL FLT NC
DL
11
UL FLT NO
Uplink FLT, Opens on FLT
4
UL COM
UL FLT Common
12
UL FLT NC
UL FLT Closes on FLT
5 SPARE
13 SPARE
6
ALOG TST
Analog voltage output, TBD
14
LNA PWR RTM
Ground, Return for LNA Power
7
EXT INPUT2
Input, logic 0 or 5V
15
EXT TWT FLT
Input, logic 0 or 5V, TWT Fault
8 GRD
Ground
5–6