KST-12000 Ku-Band Satellite Terminal

Revision 4

Operation

MN/KST12000.IOM

4.3.2.3 Faults

The FAULTS level is accessible from the SELECT menu (Table 4-4). Faults are similar
to monitor functions, as they display the current fault status of the group being displayed.

Press [

] or [

] to move between the faults.


The current faults status is displayed as “OK” or “FLT” for each parameter monitored.
“OK” indicates that no fault exists, while “FLT” indicates that a faults exists.

Press [CLEAR] to exit this level of operation and return to the previous level.

The following list outlines the faults monitored in the FAULTS menu. Refer to Chapter 6
for troubleshooting procedures for each displayed fault.

Fault

Description

RESTART

M&C microprocessor experienced a restart due to power failure or watchdog
timer time-out.

UPLINK

U/L fault caused by synth, U/C, IFLO, or HPA.

DOWNLINK

D/L fault caused by synth, D/C, IFLO, or LNA.

5V PWR

+5V power supply fault. This is a status only fault and will not turn the
transmitter OFF.

12V PWR

+12V power supply fault. This is a status only fault and will not turn the
transmitter OFF.

HPA

High Power Amplifier fault. Typically indicates that the amplifier is not present or
is not operating. This fault will turn the RF transmitter OFF.

LNA

Low noise amplifier fault. Typically indicates that the LNA is not present, has
failed, or exceeded the high or low fault window trip point. This fault will not turn
the transmitter OFF.

U/C LOCK

Up converter lock fault. Indicates the up converter is not locked up. This fault
will turn the transmitter OFF.

USV TUN

Up converter synthesizer tuning voltage. Vt-s.

UVV TUN

Up converter synthesizer tuning voltage. Vt-v.

D/C LOCK

Down converter lock fault. Indicates the down converter is not locked up. This
fault will NOT turn the transmitter OFF.

DCV TUN

Down converter synthesizer tuning voltage. Vt-s.

DVV TUN

Down converter synthesizer tuning voltage. Vt-v.

IF LOCK

IF synthesizer lock fault. This fault will turn the transmitter OFF.

IF TUN

IF tuning fault.