A.4 Status Commands/Responses

Config
Status

Command:
Response:

>add/OS_'cr'


UCF_nnnnn.n'cr'
DCF_nnnnn.n'cr'
RF_xxx'cr'
UCA_nn.n'cr'
DCA_nn.n'cr'

SEL_n'cr''lf']

The converter configuration status command causes a block of
data to be returned by the addressed RFT-1200. The block of
data reflects the current configuration status.

(nnnnn.n = 14000.0 to 14500.0 MHz.)
(nnnnn.n = 10950.0 to 12750.0 MHz.)
(xxx = ON, WRM, or OFF.)
(nn.n = 0 to 25.0 dBm UC Fine Adj.)
(Ver: 1: nn.n = 0 to 25.0 dBm DC Fine Adj. –31.0 scale)
(Ver: 2: nn.n = 0 to 31.0 dBm DC Fine Adj.)
(n = 1, 2, 3, or None.)

Fault Status

Command:
Response:

>add/FS_'cr'



RST_xxx'cr'
UL_xxx'cr'
DL_xxx'cr'
PS5_xxx'cr'
P12_xxx'cr'
HPA_xxx'cr'
LNA_xxx'cr'
ULD_xxx'cr'
USV_xxx'cr'
UVV_xxx'cr'
DLD_xxx'cr' (See

Note)

DCV_xxx'cr' (See

Note)

DVV_xxx'cr' (See

Note)

ILD_xxx'cr'
ITM_xxx'cr''lf']

This command returns a block of data reflecting the current
and logged faults. Logged faults will be reset when receiving
this command, while current faults can be read on the second
request.

xxx = OK or FLT

Unit experienced a restart

xxx = OK or FLT

Uplink fault

xxx = OK or FLT

Downlink fault

xxx = OK or FLT

+5V power supply

xxx = OK or FLT

+12V power supply

xxx = OK or FLT

Power Amp fault

xxx = OK or FLT

LNA fault

xxx = OK or FLT

UC LO Lock Detect

xxx = OK or FLT

UC LO Vt-S Tuning voltage

xxx = OK or FLT

UC LO Vt-V Tuning voltage

xxx = OK or FLT

DC Lock Detect

xxx = OK or FLT

DC LO Vt-C tuning voltage

xxx = OK or FLT

DC LO Vt-V tuning voltage

xxx = OK or FLT

IF LO Lock Detect

xxx = OK or FLT

IF LO Tuning voltage


Note: In a single synthesizer configuration, these items will
display 'DLD_N/A', 'DCV_N/A', and 'DVV_N/A', respectively.

Summary
Fault

Command:
Response:

>add/SF_xxx'cr''lf']

Where: xxx = OK or FLT.

Returns status of current faults only.

Maint
Status

Command:
Response:

>add/MS_'cr'


UCT_nn'cr'
DCT_nn'cr'
HPT_nn'cr'
USV_nn.n'cr'
UVV_nn.n'cr'
DCV_nn.n'cr' (See

Note)

DVV_nn.n'cr' (See

Note)

TIV_nn.n'cr''lf']

This command returns a block of data from the RFT-1200
reflecting the status of certain internal parameters for the
purpose of troubleshooting.

nn = UC temperature in degrees C
nn = DC temperature in degrees C
nn = Power Amp temp in degrees C
nn.n = UC LO Vt-S Tuning voltage
nn.n = UC LO Vt-V Tuning voltage
nn.n = DC LO Vt-C Tuning voltage
nn.n = DC LO Vt-V Tuning voltage
nn.n = Tuning voltage of IF LO

Note: In a single synthesizer configuration, these items will
display 'DCV_N/A' and 'DVV_N/A', respectively.