beautypg.com

2 square pole, 3 spar installation – Comtech EF Data KST-12000 User Manual

Page 68

background image

KST-12000 Ku-Band Satellite Terminal

Revision 4

Redundant System Installation

MN/KST12000.IOM

3.3.2.2 Square Pole

For square vertical pole installation, follow the steps in Section 3.3.2.1, with the
following exceptions:

• Do not perform Step 4.
• Do not perform Step 6.e.

3.3.3 Spar Installation

Note: The following process is for a typical installation. Custom kits may be ordered and
are beyond the scope of this manual.

To install the RFTs to a spar:

1. Set the units on their side, with the mounting holes facing up.

2. Install the 8” unistruts as follows:

a. Position an 8” unistrut (with the open

side facing up) over one set of the
mounting holes on the RFT.


b. Using four 1/4-20 bolts, 1/4” split

lockwashers, and 1/4” flat washers,
attach an 8” unistrut to the RFT.


Tighten the bolts firmly.


c. Repeat Steps 2.a. and 2.b. for the

remaining 8” unistruts (for a total of
four).

3–16