beautypg.com

Comtech EF Data KST-12000 User Manual

Page 50

background image

KST-12000 Ku-Band Satellite Terminal

Revision 4

Single-Thread System Installation

MN/KST12000.IOM

Table 2-2. RFT-1200 Remote Control Connector, J6

Pin

Name

Description

RS-232

RS-485

A GND

-RX/TX RX/TX

Data

B

-RX/TX RX/TX

Data

C

+RX/TX RX/TX

Data

D

CTS

+RX/TX

Clear to Send

(see Note 1 below)

E RD/RX

Receive

Data

F

RTS

Ready to Send

(see Note 1 below)

G TD/TX

Transmit

Data

H

DSR

Data Set Ready

J

GND

Ground

K

LNA Power

Output, 10V for powering LNA

(see Note 2 below)

L

EXT_PWR

Output voltage, 11V, to power RSU-503L and KP-10

M

EXT TWT FLT

Input, logic 0 or 5V, 5V = FLT, 0V = normal

(see Note 3 below)

N

EXT IN_2

Input, logic 0 or 5V, spare

(see Note 3 below)

P SPARE

N/C

R GRD

Ground

S SPARE

N/C

T

ALOG TST

Analog test voltage output

U

UL_NC

Uplink fault relay, connects to uplink COM with fault

V

UL_COM

Uplink fault relay, COMMON

W

UL_NO

Uplink fault relay, opens with fault

X

DL_NC

Downlink fault relay, connects to downlink COM with
fault

Y

DL_COM

Downlink fault relay, COMMON

Z

DL_NO

Downlink fault relay, opens with fault

a

LNA PWR RTN

Return for LNA Power

(see Note 2 below)

b SPARE

c SPARE

Notes:

1. In RS-232 mode, CTS is tied to RTS (and vice versa).
2. LNA can be powered from these pinouts instead of up through the RF cable.
3. 5V is a floating level.

2–22