beautypg.com

1 rj-45 gigabit ethernet data interface example – Comtech EF Data CRS-170A User Manual

Page 100

background image

CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Cables and Connections

Revision 13

5–30

5.5.2 Unit-to-User Data Interface Connections and Examples

In addition to the control and IF Unit-to-Switch cabling shown previously, the CDM-840 features

a single 10/100/1000 Gigabit Ethernet RJ-45 data interface port, and a G.703 Unbalanced E1

data interface for use with the CDM-840’s optional E1 Interface/RAN Optimization

Hardware/FAST Feature upgrade.

With the exception of the 10/100/1000 Gigabit Ethernet Interface configuration shown in Sect.

5.5.2.1, which requires user-provided Ethernet cables and a Layer 2 switch, you will need one

cable and component kit per 1:1 unit pair for each user interface (see examples for specified

quantities).

5.5.2.1 RJ-45 Gigabit Ethernet Data Interface Example

Figure 5-25 shows the block diagram and cabling example for a CDM-840 1:1 configuration using

the RJ-45 10/100/1000 Gigabit Ethernet port. This configuration requires no cabling and

component kit – you must make a direct connection with user-provided Ethernet cables and a

Layer 2 switch.

CDM-840 Block Diagram – Gigabit Ethernet 1:1 Operation

Figure 5-25. CDM-840 Block Diagram – Gigabit Ethernet 1:1 Operation