Page 85

background image

MCED-100 MetaCarrier Embedding Device

Revision 1

Ethernet-based Remote Product Management

MN-MCED100

6–19

Set Time (hh:mm:ss) – Use HH:MM:SS format (where HH = hour [00 to 23], MM = minutes 

[00 to 59], and SS = seconds [00 to 59]) to enter a time. 
 

Set Date (dd/mm/yy) – Use the European time format DD/MM/YY (where DD = day [01 to 

31], MM = month [01 to 12], and YY = year [00 to 99]) to enter a date. 

 
Enter the desired time and date values. Click [Submit] to save. 

Test Control

The test controls are intended for MetaCarrier debug operations only and
should not be used unless instructed by Comtech EF Data Technical Support.
Unintended operation or interference could result if these controls are used.

Frequency Offset – Provides ability to offset the MetaCarrier from the center frequency of 

the carrier. 
 

Power Ratio – Provides the ability to modify the power level of the MetaCarrier. 
 
Test Mode – The following test modes must be entered from a normal operating condition, 

in  which  the  MCED‐100  is  transmitting  a  MetaCarrier  under  a  carrier  from  an  external 
modulator. 

 

Use the drop‐down menu to select this operating mode as follows: 

 

o

Normal  Mode  –  This  mode  clears  any  test  modes,  and  places  the  unit  back  into  an 
operational state. 
 

o

Tx CW  This test mode forces transmission of  a pure MetaCarrier (unmodulated).  

 

o

Tx  Alt  1/0  –  Use  this  mode  to  check  the  carrier  suppression  of  the  external  modulator. 
This  test  mode  forces  transmission  of  a  MetaCarrier  modulated  with  an  alternating 
1,0,1,0 pattern, at 224kcps. This causes two discrete spectral lines to appear, spaced at ± 
½ the symbol/chip rate, about the carrier frequency.  

 

o

PN 224ksps – This test mode generates a pseudo‐random number sequence in place of 
the data fields in the MetaCarrier. This MetaCarrier is transmitted at 224ksps. 

 
Click [Submit] to save these settings. 
 
To reset the parameters in this section back to their default values (i.e., normal operation), click 
[restore to default value]

External GPS Serial Port

Configure the serial port dedicated for use with the optional GPS function. 
 
Baud Rate – Use the drop‐down menu to select the applicable baud rate. Values of 2400

4800960019200, 38400 and 57600 baud are available. 