Remote Commands and Queries

The Serial Interface  (the Controller), shown previously in Figure 5‐1,  is used to issue remote commands and queries to the MCDD‐100 
(the Target). From the Serial Interface command prompt MCDD‐100> type in the command or query packet, using the format explained 
previously, for transmission to the MCDD‐100. 
 
For example: MCDD‐100><0000/IPA=010.006.030.001/24 [cr] 
 
The table that follows provides a ‘quick reference‘ to the Instruction Codes available at present for M&C of the MCDD‐100. The ‘C’ and 
Q’ columns, when marked with an ‘X’, denote whether that Instruction Code is Command OnlyQuery Only, or Command and Query
 

INSTRUCTION CODE 

USED TO... 

Page 

DPW 

Resets the admin username/password to the factory defaults 

 

5‐9 

IPA 

Set or query the IP Address and network prefix for the Management | FE port 

5‐9 

IPG 

Set or query the IP Gateway Address for the Management | FE port 

5‐9 

 
These Instruction Codes are explained in complete detail in the tables that follow. Note that the Target‐to‐Controller Instruction Code 
Qualifiers, described earlier, that appear in the “Response to Command” column carry the following meanings: 
 

=   Message OK. 
?   Received OK, but invalid arguments were found. 
*   Message OK, but not permitted in current mode. 
#   Message OK, but unit is not in Remote mode. 
!   Invalid instruction. 
 
 

 

 