Comtech EF Data MCED-100 User Manual
Page 55
MCED-100 MetaCarrier Embedding Device
Revision 1
Updating Firmware
MN-MCED100
4–9
• Once the Management IP address is known – use Command‐line to PING: Type “ping
xxx.xxx.xxx.xxx” at the Command‐line prompt (where ‘xxx.xxx.xxx.xxx’ is the unit
Management IP Address).
The response should confirm whether or not the unit is properly connected and
communicating.
2. Use Command‐line to transfer (FTP) the files from the user pc to the MCED‐100:
• Type "put FW‐0000418x_MCED100.tar" (where ‘x’ denotes the revision letter) at the
Command‐line prompt, without quotes, to begin the file transfer. The process
sequences through several blocks – this may take several minutes for the transfer to
occur. Once the upgrade file is received, the image is written to Flash memory and the
unit transmits the message “UPLOAD COMPLETE.”
• Type "bye" to terminate the FTP session, and then close the Command‐line window.
3. Use the Serial Interface or the Web Server Interface ‘ADMIN | FIRMWARE’ page to verify
that the PC‐to‐Router FTP file transfer was successful.
4. Use the MCED‐100 Web Server Interface to select the firmware and reboot the unit:
A. Select the desired Boot Slot (Image):
• Go to the Web Server Interface ‘ADMIN | FIRMWARE’ page.
• Use the ‘Boot From:’ drop‐down menu to
select Latest, Slot 1, or Slot 2 (in the
Firmware Configuration section).
By default, the unit will boot from the Slot that stores the firmware version having
the latest date (Boot From: Latest). ‘Boot From:’ may also be set to force the unit to
boot up using either firmware image loaded in Slot 1 or Slot 2.
• Click [Submit] to save the setting.