6 mced-100 ground and power connections, 1 chassis ground interface – Comtech EF Data MCED-100 User Manual
Page 44

MCED-100 MetaCarrier Embedding Device
Revision 1
Rear Panel Connectors and Pinouts
MN-MCED100
3–8
3.6
MCED-100 Ground and Power Connections
3.6.1
Chassis Ground Interface
PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be connected
to the protective earth connection at all times. It is therefore imperative that the unit
is properly grounded, using the ground stud provided on the unit rear panel, during
installation, configuration, and operation.
The AC power interface provides the safety ground.
Figure 3-4. MCED Chassis Ground Interface
Use the #10‐32 stud, located adjacent to the power interface, for connecting a
common chassis ground among equipment.