2.13.7 Needle Valves

-

Removal 
Ensure that the system is depressurised before taking the 
needle valve apart. 
Loosen the 4 bolts with hexagon head counter clockwise 
to release the needle valve. 

9.17.057

page 14

 
-

Replacement 
Replace the gaskets AS‐007 and AS‐017,Viton,  
EPDM or Kalrez. 
All wetted parts have to be absolutely clean, don’t use oil 
or grease and avoid dust! 
Replace the needle valve centre before tighten the bolt 
with hexagon head by turning clockwise, tighten crosswise 
with M3 0,9 Nm. 
Now the needle valve has to be tested for leakage and function. 

 

-

Adjustment   

 

 

     

 The needle valves are adjustable  
with a slotted headscrewdriver to adjust the flow.  
The NV‐01 is also lockable with a  
nut because the fine adjustability. 

Available Needle valves

 

Model number 

Description 

NV‐01 

Kvmin 1.0x10

‐3 

,Kvmax 6.8x10

‐3 

Low flow needle valve, fine 

NV‐02 

Kvmin 5.6x10

‐3 

,Kvmax 5.6x10

‐2 

High flow needle valve, coarse 

  
 
 
 

2.13.8 Pneumatic operated shut off valves NC or NO

The actuating pressure has to be supplied with a 3/2 way valve. 
When the valve is not actuated the air actuation input has to vent. 
Actuation pressure 

:    

Minimal 

:  3  

bar(g). 

Maximal 

:  9 

bar(g). 

 
-

Removing 
Ensure that the system is depressurised before taking 
the pneumatic shut off valve apart. 
Remove the actuating pressure tubing and  loosen the 4 bolts 
with hexagon head counter clockwise to release the valve. 

 
-

Replacing 
Replace the gasket AS‐007 and AS‐017, Viton, EPDM or Kalrez. 
All wetted parts have to be absolutely clean, don’t use 
oil or grease and avoid dust! 
Replace the pneumatic shut off valve and tighten the 
bolts with hexagon head by turning clockwise, tighten 
crosswise with M3 0,9 Nm. 
Replace the actuating pressure tubing. 
Now the pneumatic shut off valve has to be tested for leakage and function. 

 

Available Pneumatic shut off valves

 

Model number 

Description 

PV‐01‐NC‐V 

Kv=0,20

 

Normally Closed Viton 

PV‐01‐NC‐E 

Kv=0,20

 

Normally Closed EPDM 

PV‐01‐NC‐K 

Kv=0,20

 

Normally Closed Kalrez 

PV‐01‐NO‐V 

Kv=0,20

 

Normally Open Viton 

PV‐01‐NO‐E 

Kv=0,20

 

Normally Open EPDM 

PV‐01‐NO‐K 

Kv=0,20

 

Normally Open Kalrez