11. Slide the MCB upright back into the slot

on the motherboard.

12. Install the screws mounting the upright

bracket to the motherboard entry tray.

.

13. Secure the upright bracket to the rear

frame with the existing hardware as
shown.

14. Reinstall all connectors to the MCB from

the labels attached to each harness applied
in step 1.

* DO NOT RECONNECT THE SENSORS
FROM THE SNAP 700 LOCATED AT
J26 TOP REFLECTIVE OPTION HOLE
J27 KNIFE HOME
J28 OPTIONAL BOTTOM REFLECTIVE
THE LINEAR KNIFE SENSORS WILL GET
PLUGGED BACK INTO THESE THREE
CONNECTOR HOUSINGS.