Maintenance

Snap Linear Knife

3.

Remove the six 8-32 Button Head Screws
and remove the left and right side covers.

4.

Remove the entry guide and deflector
bracket by swinging the carriage assembly
out and inserting a 2.5mm Allen Key or
ball driver through the holes in the frame
to gain access to the screws.

Note: The upper sensor shaft is not shown
for clarity purposes.

5.

With the entry guide removed, see the four
exposed Phillips flat head screws holding
the upper stationary blade. Remove
screws and blade with a #2 Phillips head
screw driver.

Clean the blade with Isopropyl Alcohol.
The blades are very sharp. Cut resistant
gloves should be worn to avoid injury.

6.

With the upper stationary blade removed
there is access to the disc blade. Remove
the disc blade. The bearing and spacer can
stay on the carriage assembly.

Clean the disc blade with isopropyl
alcohol.

Replace blade in same order as removed.

Note: Be careful not to move the carriage
assembly too much as the disc blade will
fall off.