beautypg.com

Avery Dennison SNAP 700 RFID Linear Knife User Manual

Page 34

background image

34

Snap Linear Knife

1. Damaged sensor

1. Replace sensor harness assembly.

Reflective sensor error

1. Sensor not aligned with mark

1. Move senor in align with registration mark

1. Sensor mark to small

1. Registration mark spec is 1/8” wide in the feed

direction and 3/8” wide across the web.

1. Sense mark contrast range to

close

1. Supplies not compatible with sensor

Knife did not home

1. Carriage may be out of sensor

range

1. Place carriage between front and back sensors.

1. Knife pulley may have become

loose missing.

1. Tighten or replace set screws on the knife

pulley.