Table 5-7, Sensor data records, Fru information and sensor data records – Artesyn RTM-ATCA-7360 Installation and Use (June 2014) User Manual
Page 80
FRU Information and Sensor Data Records
RTM-ATCA-7360 Installation and Use (6806800J08M)
80
The sensors available on the blades are detailed in the table below.
For sensor threshold definition please use the "ipmitool" found on
http://sourceforge.net/projects/ipmitool/files/ipmitool/
with
the parameter "sensor".
Table 5-7 Sensor Data Records
Sensor
Number
Sensor Name
Sensor Type
Event/Reading
Type
Event Data
Byte 1
Event Data
Byte 2
Event Data
Byte 3
Event Threshold/Description
Assertion
Deassertion
Rearm
52
+3.3V RTM
Voltage
0x02
Threshold
0x01
0xFF
0xFF
unr uc lnr lc
Asrt / Deass
Auto
53
+12V RTM
Voltage
0x02
Threshold
0x01
0xFF
0xFF
unr uc lnr lc
Asrt / Deass
Auto
54
+1.2V RTM
Voltage
0x02
Threshold
0x01
0xFF
0xFF
unr uc lnr lc
Asrt / Deass
Auto
55
+1.0V RTM
Voltage
0x02
Threshold
0x01
0xFF
0xFF
unr uc lnr lc
Asrt / Deass
Auto
56
temp in RTM
Watchdog 2
0x23
Threshold
0x01
0xFF
0xFF
uc unc unr
Asrt / Deass
Auto
57
temp SAS
Voltage
0x02
Threshold
0x01
0xFF
0xFF
uc unc unr
Asrt / Deass
Auto
58
temp ETH
Voltage
0x02
Threshold
0x01
0xFF
0xFF
uc unc unr
Asrt / Deass
Auto
59
Hot Swap HDD
Voltage
0x02
Sensor-specific
discrete
0x6F
0x0
0xFF
0xFF
0x0: Hotswap HDD detected
Asrt
Auto
Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold