beautypg.com

Table 5-7, Sensor data records, Fru information and sensor data records – Artesyn RTM-ATCA-7360 Installation and Use (June 2014) User Manual

Page 80

background image

FRU Information and Sensor Data Records

RTM-ATCA-7360 Installation and Use (6806800J08M)

80

The sensors available on the blades are detailed in the table below.

For sensor threshold definition please use the "ipmitool" found on

http://sourceforge.net/projects/ipmitool/files/ipmitool/

with

the parameter "sensor".

Table 5-7 Sensor Data Records

Sensor

Number

Sensor Name

Sensor Type

Event/Reading

Type

Event Data

Byte 1

Event Data

Byte 2

Event Data

Byte 3

Event Threshold/Description

Assertion

Deassertion

Rearm

52

+3.3V RTM

Voltage
0x02

Threshold
0x01

0xFF

0xFF

unr uc lnr lc

Asrt / Deass

Auto

53

+12V RTM

Voltage
0x02

Threshold
0x01

0xFF

0xFF

unr uc lnr lc

Asrt / Deass

Auto

54

+1.2V RTM

Voltage
0x02

Threshold
0x01

0xFF

0xFF

unr uc lnr lc

Asrt / Deass

Auto

55

+1.0V RTM

Voltage
0x02

Threshold
0x01

0xFF

0xFF

unr uc lnr lc

Asrt / Deass

Auto

56

temp in RTM

Watchdog 2
0x23

Threshold
0x01

0xFF

0xFF

uc unc unr

Asrt / Deass

Auto

57

temp SAS

Voltage
0x02

Threshold
0x01

0xFF

0xFF

uc unc unr

Asrt / Deass

Auto

58

temp ETH

Voltage
0x02

Threshold
0x01

0xFF

0xFF

uc unc unr

Asrt / Deass

Auto

59

Hot Swap HDD

Voltage
0x02

Sensor-specific
discrete
0x6F

0x0

0xFF

0xFF

0x0: Hotswap HDD detected

Asrt

Auto

Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold
Deass: Deassertion Lnr: Lower non-recoverable threshold Lc: Lower critical threshold Lnc: Lower non-critical threshold

This manual is related to the following products: