Introduction – Artesyn RTM-ATCA-7360 Installation and Use (June 2014) User Manual
Page 26

Introduction
RTM-ATCA-7360 Installation and Use (6806800J08M)
26
NEBS Standard GR-63-CORE
1
ETSI EN 300019 series
NEBS level three
Product is designed to support NEBS level three. The
compliance tests must be done with the customer target
system.
PICMG 3.0 and 3.1
Defines mechanics, blade dimensions, power distribution,
power and data connectors, and system management
1. The blade does not fulfill the "Unpacked Equipment Shock Criteria" as defined in NEBS GR63 4.3.2. During tests
which consisted of dropping the blade from 100 mm height, we observed that on some blades the ATCA zone 2 and
3 connectors got damaged. Although it was possible to manually repair the connectors and the blade was fully
functional again afterwards, the criteria imposed by the NEBS standard were not fulfilled.
Table 1-1 Standard Compliances (continued)
Standard
Description
To fulfill the requirements of Telcordia GR-1089,R4-14, use Shielded Twisted Pair (STP)
cables grounded at both ends to connect to the Ethernet ports.
The product has been designed to meet the directive on the restriction of the use of
certain hazardous substances in electrical and electronic equipment (RoHS) Directive
2002/95/EC.