Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
+5 °C (41 °F) to +40 °C (104 °F) (normal
operation) according to NEBS Standard
GR-63-CORE
-5 °C (23 °F) to +55 °C (131 °F)
(exceptional operation) according to
NEBS Standard GR-63-CORE
-40 ºC (-40 °F) to +70 °C (158 °F) (may be
further limited by installed accessories)
Temp. Change
+/- 0.25 °C/min according to NEBS
Standard GR-63-CORE
+/- 0.25 °C/min
Rel. Humidity
5% to 90% non-condensing according
to Artesyn-internal environmental
requirements
5% to 95% non-condensing according to
Artesyn-internal environmental
requirements
Vibration
0.1 g from 5 to 100 Hz and back to 5 Hz
at a rate of 0.1 octave/minute
5-20 Hz at 0.01 g
2
/Hz
20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 m
2
/Sec
3
Random 20-200 Hz at -3 m/Sec
2
Shock
Half-sine, 11 m/Sec, 30mSec/Sec
2
Blade level packaging
Half-sine, 6 mSec at 180 m/Sec
2
Free Fall
-
1,200 mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(blade level packaging)
100 mm (unpacked) per GR-63-CORE