5.5.2.3

PEI Beep Codes

0xF3

Recovery firmware image found.

0xF4

Recovery firmware image loaded.

0xF5 - 0xF7

Reserved for future AMI progress codes.

Recovery Error Codes

0xF8

Recovery PPI is not available.

0xF9

Recovery capsule is not found.

0xFA

Invalid recovery capsule.

0xFB - 0xFF

Reserved for future AMI error codes.

Table 5-33 PEI Status Codes (continued)

Status Code

Description

Table 5-34 PEI Beep Codes

# of Beeps

Description

1

Memory not Installed.

1

Memory was installed twice (InstallPeiMemory routine in PEI Core called
twice).

3

DXEIPL was not found.

3

DXE core firmware volume was not found.

7

Reset PPI is not available.

4

Recovery failed.

4

S3 resume failed.