Hardware Preparation and Installation

MITX-430/MITX-440-DVI-2E Installation and Use (6806800K37D)

39

Prepare the components to be installed or replaced.
When you hold or transport the components, use the special antistatic package.
Prepare the cross screwdriver, screws, plastic supports, cooling gel, and ESD-preventive
wrist strap.

Confirm installation or changing position
Confirm the position where the MITX-430/MITX-440-DVI-2E will be installed.

Others
If a serious problem occurs and cannot be solved when you install or replace the
component, contact Artesyn Embedded Technologies for technical support.

2.5

Processor Cooler Installation and Removal

Installing the Processor Cooler

1. Wear the ESD-preventive wrist strap.

2. Tear down the thermal pad resistant paper from back of the cooler.

3. Adjust the optimal installation direction for cooler. Place the cooler over the processor and

align the two push-pins to the holes on the motherboard.

4. Push the two pins down and make sure that each of the push-pin is inserted correctly into

the hole and properly locked on the motherboard.

5. Connect the fan to its connector on the motherboard.

Removing the Processor Cooler

1. Wear the ESD-preventive wrist strap.

2. Disconnect the fan from the motherboard.

3. Turn over the motherboard to backside. Locate the cooler pins, pinch the ends of the push

tabs and push them out of the hole.