Operation – Artesyn MITX-430/MITX-440-DVI-2E Installation and Use (August 2014) User Manual
Page 88

Operation
MITX-430/MITX-440-DVI-2E Installation and Use (6806800K37D)
88
Bits per second
Selects serial port transmission speed. The speed must be matched on
the other side. Long or noisy lines may require lower speeds.
9600
19200
57600
115200
Default value is 115200.
Data Bits
Data bits of 7 and 8. Default is 8.
Parity
Parity bit is sent with the data bits to detect some transmission errors.
Even: parity bit is 0, if the number of 1s in the data bits is even.
Odd: parity bit is 0, if number of 1s in the data bits is odd.
Mark: parity bit is always 1.
Space: Parity bit is always 0.
Mark and Space Parity do not allow for error detection. They can be used
as an additional data bit.
None
Even
Odd
Mark
Space
Default value is None.
Stop Bits
Stop bits indicate the end of a serial data packet. (Start bit indicates the
beginning). The standard setting is 1 stop bit. Communication with
slow devices may require more than 1 stop bit. The options are 1 and 2.
Default value is 1.
Flow Control
Flow control prevents data loss from buffer overflow. While sending
data, if the receiving buffers are full, a stop signal is sent to stop the data
flow. Once the buffers are empty, a start signal is sent to restart the flow.
Hardware flow control uses two wires to send start/stop signals.
Options are None and Hardware RTS/CTS.
Default value is None.
Terminal Resolution
Remote Terminal Resolution, 80x25 (default).
Table 5-24 COM1 and COM2 Console Redirection Settings (continued)
Field
Description