U-Boot Firmware

ATCA-F120 Installation and Use (6806800D06J)

98

Furthermore, information about the POST status can be obtained by reading the SYS FW
PROGRESS IPMI sensor. Depending on the POST status, this sensor holds the following values.

Table 5-4 Post Results in SYS FW PROGRESS IPMI Sensor Reading Data

Value

Description

0x01

No memory detected

0x02

Memory error. The address and data line test failed.

0x0b

U-boot image CRC mismatch detected

0x0D

Wrong CPU speed.

0xfd

Artesyn specific POST error code. Further information is
provided in the event data byte 3 (see

Table "SYS FW

PROGRESS IPMI Sensor - POST Error Event Codes" on
page 98

)

0x00

One of the remaining POST errors was detected.

Table 5-5 SYS FW PROGRESS IPMI Sensor - POST Error Event Codes

Event Data (Byte 3)

Description

0x1E

Error accessing the switch devices

0x03

Error in network loop back test

0x20

Error in network PHY test

0x1F

Error in glue logic (FPGA) test

0x0A

Error in I2C bus test

0x16

Error in RTC test

0x09

Error in flash test

0x21

Error in CPU test

0x22

Error in PCI bus test