Hardware Preparation and Installation

ATCA-F120 Installation and Use (6806800D06J)

44

The blue LED blinks when the handle is locked in position indicating module
detection and activation by the carrier board.

10.Observe blue LED status/activity. The module is fully installed when the blue LED

stops blinking and stays OFF.

Removal Procedure

The following describes how to remove an AMC module from the ATCA-F120. The procedure
assumes that the ATCA-F120 is powered. If it is not powered, the steps regarding the blue LED
can be ignored and skipped.

1. Make sure you are in an ESD safe environment.

2. Remove any cables that are connected to the AMC module face plate connectors.

3. Gently pull the module latch outwards, approximately 3mm from its locked

position.

4. Wait for the blue LED to first perform short blinks, and then glow persistently.

Data Loss
Removing the blade with the blue LED still blinking causes data loss.