beautypg.com

9 base interface extension, 1 port assignment, 2 shelf manager cross connection – Artesyn ATCA-F120 Installation and Use (August 2014) User Manual

Page 78: Table 4-5, Base interface extension - port assignment, Shelf, Manager cross connection, Functional description

background image

Functional Description

ATCA-F120 Installation and Use (6806800D06J)

78

4.9

Base Interface Extension

The ATCA-F120 provides an additional switch device: the Broadcom BCM5385. It is connected
to the previously described BCM56502 devices and is used to provide additional Ethernet
interfaces.

4.9.1

Port Assignment

The following table shows how the Ethernet ports of the BCM5385 device are assigned.

4.9.2

Shelf Manager Cross Connection

The ATCA-F120 provides two different options for the interconnection of the shelf managers
(ShM) in a system. The selection between these two options is done via an on-board
configuration switch and via an OEM IPMI command, where the OEM IPMI command overrides
the on-board switch if both settings are different. Refer to section

Configuring the Blade

on page

28

and the ATCA-F120: Control via IPMI Programmer’s Reference for further details.

ge23

SERDES

Base interface update
channel

1000Base-T

xe0

SERDES

RTM

XAUI

xe1

SERDES

RTM

XAUI

Table 4-4 Base Channel Switch Port Assignment (continued)

Physical Port

PHY/SERDES

Destination

Interface Type

Table 4-5 Base Interface Extension - Port Assignment

Port

Destination

Interface Type

1

Base Interface Channel #1 Port 0

100Base-TX

2

Base Interface Channel #1 Port 1 or Update Channel #0. See

Shelf

Manager Cross Connection

on page 78

for further details.

100Base-TX

3

Broadcom BCM56502, physical port ge0

1000Base-T

4

Face Plate

1000Base-TX

5

not connected

-