9 base interface extension, 1 port assignment, 2 shelf manager cross connection – Artesyn ATCA-F120 Installation and Use (August 2014) User Manual
Page 78: Table 4-5, Base interface extension - port assignment, Shelf, Manager cross connection, Functional description

Functional Description
ATCA-F120 Installation and Use (6806800D06J)
78
4.9
Base Interface Extension
The ATCA-F120 provides an additional switch device: the Broadcom BCM5385. It is connected
to the previously described BCM56502 devices and is used to provide additional Ethernet
interfaces.
4.9.1
Port Assignment
The following table shows how the Ethernet ports of the BCM5385 device are assigned.
4.9.2
Shelf Manager Cross Connection
The ATCA-F120 provides two different options for the interconnection of the shelf managers
(ShM) in a system. The selection between these two options is done via an on-board
configuration switch and via an OEM IPMI command, where the OEM IPMI command overrides
the on-board switch if both settings are different. Refer to section
and the ATCA-F120: Control via IPMI Programmer’s Reference for further details.
ge23
SERDES
Base interface update
channel
1000Base-T
xe0
SERDES
RTM
XAUI
xe1
SERDES
RTM
XAUI
Table 4-4 Base Channel Switch Port Assignment (continued)
Physical Port
PHY/SERDES
Destination
Interface Type
Table 4-5 Base Interface Extension - Port Assignment
Port
Destination
Interface Type
1
Base Interface Channel #1 Port 0
100Base-TX
2
Base Interface Channel #1 Port 1 or Update Channel #0. See
for further details.
100Base-TX
3
Broadcom BCM56502, physical port ge0
1000Base-T
4
Face Plate
1000Base-TX
5
not connected
-