background image

PT-Basic Programming Manual Ver. 1.00

42/143

SYS_SUSPEND

Purpose: To shut down the system.

Syntax: SYS_SUSPEND

Example: SYS_SUSPEND

Description: This command will shut down the system.

CHECK_AID

Purpose: To check the agency ID is correct or not.

Syntax: A%=CHECK_AID(S1$ , S2$)

Example: IF CHECK_AID("6421","08724") THEN

PRINT "AID OK..."

ELSE

PRINT "AID NG..."

END IF

WHILE INKEY$=""

WEND

Description: A% is an integer variable to be assigned to the result.

A%

Meaning

0

AID not

correct.

1

AID correct.

S1$ is a string variable, indicating the UserID that needs 4~8

characters.

S2$ is a string variable, indicating the password that needs

4~8 characters.