Argox PA-20 Basic Programming Manual User Manual
Page 132

PT-Basic Programming Manual Ver. 1.00
131/143
Parameter1
Parameter2
Alphanumeric Entry
31
RSS Expanded
1
Read
0: Disable *
1: Enable
4
Max. code length
0 ~ 99
99 *
5
Min. code length
0 ~ 99
1 *
6
Truncate leading
0 ~ 15
0 *
7
Truncate ending
0 ~ 15
0 *
8
Code ID setting
0x00 ~ 0xff ASCII code(1 or 2
bytes)
11
UCC/EAN 128
emulation
0: Disable *
1: Enable
32
Italian Pharmacode
1
Read
0: Disable *
1: Enable
4
Max. code length
0 ~ 64
12 *
5
Min. code length
0 ~ 64
9 *
6
Truncate leading
0 ~ 15
0 *
7
Truncate ending
0 ~ 15
0 *
8
Code ID setting
0x00 ~ 0xff ASCII code(1 or 2
bytes)
10
Leading “A”
0: Disable *
1: Enable