beautypg.com

Alarm output, Digital interfaces (p models only), General – AMETEK XDL Series II User Manual

Page 9

background image

8

ALARM OUTPUT

Isolated rear-panel open-collector output signal. User can select output to be activated for either
OVP, OCP, Overtemperature or Sense miswiring, or for any of those four faults.

DIGITAL INTERFACES (P models only)

Full digital remote control facilities are available through the RS232, USB, LAN and GPIB interfaces.

General

RS232:

Standard 9-pin D-connector. Variable Baud rate (600 to 19200).

GPIB:

Conforming with IEEE488.1 and IEEE488.2

USB:

Standard USB 2.0 hardware connection. Operates as a virtual COM port.

LAN:

Ethernet 100/10base-T hardware connection. Auto speed detect, auto
MDIX. LXI V1.2, Class C compliant.

Remote Command
Processing Time:

Typically <25ms between receiving the command terminator for a step
voltage change at the instrument and the output voltage beginning to
change.

Status Indication:

Remote mode and LAN status indicators

Main Outputs

Voltage Setting:

16-bit; Resolution 1mV, accuracy ± (0·03% +5mV)

Current Setting:

16-bit; Resolution 0.1mA, accuracy ± (0·2% + 5mA)

Resolution 0.01mA, Accuracy ± (0·2% + 0·5mA) on 500mA range.

Readback V & I

See meter specifications.

Auxiliary Output (T models only)

Voltage Setting:

Resolution 10mV, accuracy ± 0.5% ±10mV

Current Setting:

Resolution 10mA, accuracy ± 0.5% ±10mA

Readback V & I

See meter specifications

GENERAL

AC Input:

230V AC or 115V AC ± 10%, 50/60Hz
Installation Category II

Power Consumption:

Single output: 250VA max; Triple output: 500VA max.

Operating Range:

+5ºC to +40ºC, 20% to 80% RH

Storage Range:

−40ºC to + 70ºC

Environmental:

Indoor use at altitudes up to 2000m, Pollution Degree 2.

Cooling:

Intelligent variable-speed fan. Over-temperature trip shuts down
output if internal temperatures exceed predetermined thresholds.

Store/Recall:

Up to 50 set-ups each main output, 50 linked set-ups, and 10 auxiliary
output settings can be saved and recalled via the keyboard or remote
interfaces.

Safety:

Complies with EN61010

−1

EMC:

Complies with EN61326

Size:

Single output: 140 x 160 x 290mm (WxHxD), excl. feet & terminals.
Triple output: 280 x 160 x 290mm (WxHxD), excl. feet & terminals

Weight:

Single: 5.5kg; Triple: 10·5kg