Appendix m – connectors and indicators – WaveWare SPS-5 v9E User Manual
Page 54

Appendix M – Connectors and Indicators
SPS-5 v
9E Paging
System:
LED Indicators:
POWER:
GREEN LED
– Shows Power is Applied
RF TX:
GREEN LED
– Shows Transmission of Page
RF CD:
GREEN LED
– Shows Carrier Detect
DATA 1:
GREEN LED
– Port 1 RS-232 Cable is Attached
PROGRAM:
RED LED
– Shows when In/Out of
Programming Mode and Rebooting System and it also
lights up if an Error is found within the Encoder System.
ETHERNET CONNECTOR:
GREEN LED
and
ORANGE
LED
indicate normal operation
RS-232 DB-9 Connector Pin-Out:
1 CD
(not used)
2 RD
(data output by paging encoder, typically required)
3 TD
(data received by paging encoder, required)
4 DTR
(not used)
5 GND
(required)
6 DSR
(signal output by paging encoder, requirement
depends on host system)
7 RTS
(signal input to paging encoder, required only if
hardware flow control mode is active)
8 CTS
(signal output by paging encoder, required only if
hardware flow control mode is active)
9 RI
(not used)