Quick start guide for web browser programming – WaveWare SPS-5 v9E User Manual
Page 10

Note: Do not attempt to operate the paging system without the antenna connected to the paging transmitter,
as damage to the paging transmitter may occur.
Remove the Front Cover of the Transmitter Unit. Hold the unit up against the wall or other non-metallic
vertical surface as a template to mark the 2 hole locations where you will mount the Transmitter Unit. Drill and
attach the top # 8 x ¾” sheet metal screw to the wall or vertical surface (use the plastic anchors if needed).
Mount the Transmitter Unit onto the top screw, using the 1 Slotted mounting hole near the top of the unit
inside the enclosure. Then attach the 2
nd
screw into the round hole near the bottom of the unit inside the
enclosure and tighten both screws. Re-attach the Front Cover of the Transmitter unit.
Plug the RS-232 Cable into an available DB9 serial port connector on the back of a Host Device, such as a
PC or Nurse Call system or other Host Device. If the serial port has a DB25 connector, you must provide a
DB25 to DB9 adapter, which is available from WaveWare or from a computer supply company. Tighten the
connector screws.
Plug the RS-232 Cable into the DB9 female connector on the Transmitter Unit. Tighten the connector screws.
Plug the Power Supply into a 110 VAC power outlet. The
GREEN
colored Power LED Indicator on the
Transmitter Unit should be illuminated when power is properly applied.
Program the pager database and other encoder settings, if required. There are two programming methods
available: 1) using a web browser, and 2) using WaveWare Paging v
9
Encoder Setup Software, which is
available from the WaveWare Product Support CD or from our Website, at
http://www.wirelessmessaging.com/wavewaresw.html
If you are using a PC as a Host Device, load paging control software, such as WaveWare Enterprise
Messaging Software, on the PC and configure it to operate with your WaveWare v9E
Paging System. Make
sure the proper serial port settings are defined. The
GREEN
colored RF TX LED Indicator on the Transmitter
Unit should illuminate for about 3-4 seconds during a normal paging transmission. If the Carrier Detect
function is enabled, you may see the
GREEN
colored RF CD LED Indicator temporarily illuminate prior to
some paging transmissions, if a carrier signal is detected from a nearby transmitter at the same frequency as
your WaveWare v9E
Paging System.
Quick Start Guide for Web Browser Programming
Your
SPS- 5
v9E Paging System should include:
1- Rubber Duck Style Antenna, 1- Power Supply, 1- Serial Cable, 1- Ethernet Cable, 1- Package of Mounting
Hardware and 1- Product Support CD.
Notes:
The Frequency, Cap Code(s), Watts and other Information are
“Labeled”
on the Back of the unit.
Installation:
The
SPS-5
has Mounting Holes on the Back of the Unit for Wall Mounting.
Remove the Front Cover to access these Mounting Holes and use the Screws and Anchors provided.
Programming
the
SPS-5
Paging System Using a Web Browser:
1) Enter the IP address of the paging system in the browser as a URL and press Enter, e.g. 192.168.10.115
2) Use the Discover function in the Encoder Setup Software to discover the IP address of the paging system, when it is
either connected to the LAN or when it is connected directly to the PC’s Ethernet port that the Encoder Setup
Software is running on.
3) If the IP address of the paging system is not on the same subnet as the LAN, then you can either use the Encoder
Setup Software to reprogram the paging system IP address. or you can connect the paging system’s Ethernet port
directly to the Ethernet port of the PC and change the PC’s Ethernet address to be on the same subnet as that of the
paging system, e.g. If the paging system is at 10.10.1.23, you can change the PC’s IP address to something like
10.01.1.24.
The browser interface for the SPS-5 v9E Paging System has multiple configuration pages. Click on the tabs at the top of
each page to access each page.