beautypg.com

Setup command, Example 1, Example 2 – WaveWare SPS-5 v9E User Manual

Page 43

background image


07 =

EEPROM Write Error.

Indicates an internal system error in the paging encoder with regard to the

proper storage of configuration information. This condition would likely indicate that paging
encoder repair is required.

08 =

Invalid Command Format.

Indicates that the command was not fully recognized as a valid

paging encoder command.

Example 1:

A,5,46180,This is a testV8.01,00,0,1,1A

Echoes the paging message command and acknowledges proper receipt of a command by appending
the ACK, indicating paging encoder firmware version is 8.01, no paging messages in queue, no carrier
signal is being detected, and Carrier Detect mode is set to “ON”. The last field does not currently
provide useful information.

Example 2:

4,5,000000603

Echoes the paging message command and indicates an error in receiving a command due to an invalid
paging receiver capcode in a Paging Message command. Includes a and at the end of the
response string if they were included in the paging message command.

SETUP COMMAND

You may program the WaveWare v9E

Paging Encoders to monitor for interference using the Carrier Detect mode. If

the Carrier Detect mode is turned “ON”, the paging encoder will hold paging messages in queue until an offending
carrier signal is no longer detected at the transmission frequency of the paging encoder. The settings programmed by
the Setup command will be remembered by the paging encoder even if power is removed from the paging encoder.

The Setup command is formatted as follows:

S,X,V

Where the S indicates Setup Mode, X is the command type, and V is the value. The comma delimiters are
optional.

X

A single numeric value used to indicate the command type. The numeric character is followed by
a comma.

Valid values (X) are:

1 =

Carrier Detect Mode

V

A single numeric value used to indicate the value of the command setting to be saved. The
numeric character is followed by an EOT character.
Valid values (V) are:

0 =

Off

1 =

On