beautypg.com

Selftest and calibration – Dataman 48Pro User Manual

Page 18

background image


Note: Pin no. 1 is indicated by a triangle on ISP cable
connector
.

Dataman-48Pro

ISP

cable

Warnings:

When you use Dataman-48Pro as ISP programmer, do

not insert device into ZIF socket.

When you program devices into ZIF socket, do not insert

ISP cable to ISP connector.

Use only attached ISP cable. When you use another ISP

cable (other material, length…), programming may be
unreliable.

Dataman-48Pro can supply programming voltage (pin 1 of

ISP connector) and target system voltage (pin 5 of ISP
connector) with some limitations (see Technical
specification / ISP connector), but target system should
not supply voltage to the Dataman-48Pro
.

Dataman-48Pro applies programming voltage to the target

device. If the programming voltage is different than
expected, the Dataman-48Pro will abort the operation.


Note: H/L/read Dataman-48Pro driver

C1

R1

H/L/read driver
in programmer

pin of ISP
connector

PU/PD driver
in programmer

R2

Selftest and calibration

If you feel that your programmer does not work properly,
please run the programmer selftest using the Diagnostic POD.
The Diagnostic POD is included with the standard package.
For optimal results, we recommend you run the programmer
selftest and calibration every 6 months. See instructions for
selftest in the Diagnostics menu of PG4UW.

18