beautypg.com

Link management packet size, Link management packet payload format, Link management packet type (lmp[23:20]) – Altera SerialLite II Protocol User Manual

Page 39: Link management packet parameter (lmp[19:8]), D, as shown in

background image

Altera Corporation

39

SerialLite II Protocol Reference Manual

SerialLite II Specification

Figure 2–18. Link Management Packet Encapsulation

Link Management Packet Size
The link management packet has a fixed length of four bytes: a single byte
identifier followed by three bytes of payload.

Link Management Packet Payload Format

Table 2–18

shows the link management packet payload format using the

following parameters:

FC_TIME = Flow control time

ACK = Acknowledgement

NACK = Negative acknowledgement

SID = Segment identification

BIP-8 = 8 bits of bit interleaved parity

CLASS = Packet type class

Link Management Packet Type (LMP[23:20])
SerialLite II currently has the following management packets defined:

Flow Control Packets (Link Packet Type = 0x1); see detailed
description in

“Flow Control (Optional)” on page 2–61

.

Retry-on-Error Control Packets (Link Packet Type = 0x2); see
detailed description in

“Retry-on-Error (Optional)” on page 2–64

.

Link Management Packet Parameter (LMP[19:8])
This field contains parameters specific to the type of link management
packet. See

“Flow Control (Optional)” on page 2–61

and

“Retry-on-Error

(Optional)” on page 2–64

for details.

SLP

Link Management Packet Payload

Table 2–18. Link Management Packet Format

Bits

[23:20]

[19:16]

[15:12]

[11:8]

[7:4]

[3:0]

Type

Parameter Description

Protection

Flow control packet

0x1

CLASS

FC_TIME

BIP-8

Retry-on-error control packet

0x2

CLASS

0x0

SID

BIP-8